VISTA 4120XM 4140XMP DEMCO. This feature is useful if this Manual is not accessible when you need to perform a procedure with which you are not familiar.-6. Panic functions by your installer (see PANIC section on page 29). IMPORTANTI: When entering codes and commands.
0.75 to 1.25 tons
Up to 20.9 SEER / 11.7 HSPF
VISTA is a remarkable blend of iconic design and engineering excellence with an elegant white or a silver and white finish. Fitting within the ceiling grid and discreetly mounted to the ceiling itself, VISTA is stylish, low profile, and compact. High efficiency and comfort is delivered through the combined use of floor and presence sensors (optional). It is also possible to close individual louvers via the wired remote control for personalized comfort.
ENERGY STAR® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency. ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Products that earn the ENERGY STAR prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S. Environmental Protection Agency.
Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit
www.energystar.gov.
Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit
www.energystar.gov.
DKN Cloud WiFi Adaptor Compatible with DKN Cloud WiFi Adaptor The DKN Cloud Wi-Fi Adaptor enables the remote control of your Daikin indoor units through an iOS/Android App. |
- Seamless integration in standard architectural ceiling tiles, leaving only 5/16'
- High efficiencies with up to 20.9 SEER and up to 11.7 HSPF
- Cooling Range: 50° - 115° F (Extended operation to -4° - 115° F with facility setting and air adjustment grille)
- Heating Range: 5° - 65° F
- Energy efficient thanks to specially developed small tube heat exchanger, DC fan motor and two optional intelligent sensors
- Remarkable blend of iconic design and engineering excellence with an elegant finish in white or a combination of silver and white
- No optional adaptor needed for DIII-connection, link your unit into the wider building management system
- Fresh air integration possible
- 12-Year Parts Limited Warranty
Marketing
Engineering
Controls
Single Zone
I need a new transformer for my Honeywell Vista alarm panel, what kind do I need to purchase?
Honeywell panels use a 16.5 volt transformer, typically either a 25vA or 40vA model. Transformers aren't proprietary, so any brand will work. The only real requirement is its voltage rating (16.5 volts) at a minimum of 25vA current output.
My motion detector is false alarming, how do I fix it?
Most alarm systems have standard PIR type motion detectors that function by detecting a person's body heat as it moves along the cooler background of walls, floors, and furniture. The problem is that a PIR can be fooled by any number of environmental issues.
Check for:
Honeywell panels use a 16.5 volt transformer, typically either a 25vA or 40vA model. Transformers aren't proprietary, so any brand will work. The only real requirement is its voltage rating (16.5 volts) at a minimum of 25vA current output.
My motion detector is false alarming, how do I fix it?
Most alarm systems have standard PIR type motion detectors that function by detecting a person's body heat as it moves along the cooler background of walls, floors, and furniture. The problem is that a PIR can be fooled by any number of environmental issues.
Check for:
- A heater vent blowing on the detectors lens
- A heater vent blowing on a plant or curtain near the detector
- Spider webs near the detector, or live insects that may crawl over the detector
- Plants that are too close to the detector
One of my doors no longer acivates the alarm system, how do I fix it?
The internals of a door or window contact are very fragile and can be damaged by something as simple as the static charge from lightning striking nearby. The bad contact will either remain closed when it should trip, or remained tripped when it should be closed. Sometimes it'll even fall somewhere in the middle by adding adding resistance on closure, or never fully opening when tripped. Long story short, if you have a bad contact you can replace it easy enough. Most residential contacts are 3/8' recessed press fit contacts.
- Pry out the contact using a small flat head screwdriver
- Cut its two wires near the contact
- Strip back about 1/4' of insulation on each wire
- Use a Terminal Type 3/8' Contact as a replacement (either wire to either terminal)
- Press the new contact back into the original hole